BQLHC - RE-MOV, 0899
- MSDS: BQLHC
- Manufacturer: SELIG CHEMICAL INDUSTRIES
- Product Name: RE-MOV, 0899
- National Stock Number: 6850-00N035740
Product Identification
Product ID:RE-MOV, 0899
MSDS Date:03/27/1991
FSC:6850
NIIN:00N035740
MSDS Number: BQLHC
Responsible Party
ATLANTA, GA 30378
US
Emergency Phone: 404-691-9220;800-424-9300(CHEMTREC)
Info Phone: 404-691-9220
Cage: 86938
Contractor
Telephone: 404-691-9220
Cage: 86938
Ingredients
ETHANOL, 2-BUTOXY-; (ETHYLENE GLYCOL MONOBUTYL ETHER)
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 10-15%
OSHA PEL S, 50 PPM
ACGIH TLV: S, 25 PPM; 9293
POTASSIUM HYDROXIDE
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 1-3%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ETHANOL,2-AMINO-; (MONOETHANOLAMINE)
CAS: 141-43-5
RTECS: KJ5775000
Fraction By Weight: 5-10%
OSHA PEL 3 PPM
ACGIH TLV: 3 PPM
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: CORROSIVE TO SKIN. EYES:
CORROSIVE TO EYES. INHAL: CAN CAUSE DIZZINESS, NAUSEA & HEADACHE
UPON PROLONGED EXPOSURE. INGEST: CORROSIVE TO THROAT AND STOMACH.
ANIMAL STUDIES HAVE CLEARLY DEMONSTRAT ED DOSE-RELATED ADVERSE EFTS
ON CNS, HEMATOPOIETIC TISSUE, BLOOD, KIDNEYS, & LIVER ASSOCIATED
W/ADMIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: OF ETHYLENE GLYCOL MONOBUTYL ETHER
(EGBE). (EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO. 90-118) .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN: RINSE IMMEDIATELY WITH WATER. SEEK MEDICAL ATTENTION.
EYES: FLUSH IMMEDIATELY WITH PLENTY OF WATER FOR AT LEAST 15 MIN.
CONSULT PHYSICIAN. INHAL: MOVE TO FRESH AIR. GIVE OXYGEN, IF
NEEDED. SEE M D. INGEST: RINSE MOUTH AND GIVE PLENTY OF WATER,
FOLLOWED BY 1 OZ VINEGAR IN WATER. DO NOT INDUCE VOMITING.
IMMEDIATELY SEEK MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE @ BOIL
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:ABSORB SPILL WITH AN ABSORBENT MATERIAL (I.E.
SELIG'S AP ABSORB); PICK UP & DEPOSIT IN A SEALABLE CONTR FOR DISP
AS A HAZ WASTE. THORO CLEAN AREA W/A DETERGENT SOLN. RINSE AREA
THORO WITH CLEAN WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. HARMFUL
IF SWALLOWED. AVOID CONTACT W/SKIN/EYES. USE W/CAUTION ON ASPHALT
TILE TO AVOID BRTHG. USE ONLY AS DIRECTED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NOT REQUIRED. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LENGTH FSHLD
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
WASTE DISP METH: LOCAL, STATE & FEDERAL AGENCIES FOR PROPER DISPOSAL
PROCEDURES IN YOUR AREA. IF COMPANY EFFLUENT IS ULTIMATELY TREATED
BY A PUBLICLY OWNED SEWAGE TRTMT PLANT, SPENT PROD MAY BE NEUTRA
LIZED & DISCHARGED TO SEWER.
Chemical Properties
Boiling Pt:B.P. Text:200F,93C
Spec Gravity:1.04
pH:12
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS TO PALE YELLOW, CHARACTERISTIC
ODOR.
Percent Volatiles by Volume:93
Stability
Stability Indicator/Materials to Avoid:YES
ACID.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:UNUSED PROD MAY HAVE TO BE ABSORBED ON AN INERT
MATL (SELIG'S AP ABSORB) & DISPSOED OF AS HAZ WASTE.SM HAZ WASTE
GENERATORS SHOULD CONSULT C.F.R TITLE 40, PT 261.5 FOR POSS
EXEMPTION. SINCE REGS VARY CONCERNING DISP OF THESE CHEM, CONSULT
(SUPP DATA)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.